Fineness of Hydraulic Cement by Air Permeability Apparatus. ASTM C 11 Standard Test Methods for Fineness of Hydraulic Cement by Air Permeability Apparatus – Download as PDF File .pdf), Text File .txt) or read. ASTM C Standard Test Methods for Fineness of Hydraulic Cement by Air- Permeability Apparatus. standard by ASTM International.

Author: Mami Tugrel
Country: Denmark
Language: English (Spanish)
Genre: Love
Published (Last): 2 June 2018
Pages: 152
PDF File Size: 12.19 Mb
ePub File Size: 3.60 Mb
ISBN: 740-3-60580-267-7
Downloads: 4678
Price: Free* [*Free Regsitration Required]
Uploader: Akinojar

Caution should be taken when handling mercury and mercury containing products. The U-tube manometer shall be constructed according to the design indicated. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine aastm applicability of regulatory limitations prior to use.

The filter paper disks shall be circular, with smooth edges, and shall have the same diameter as the inside of the cell. Link to Active This link will always route to the current Active version of the standard.

ASTM C204 – 17

ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. However, the user should exercise judgement in determining its suitability with regard to fineness measurements of cements with densities, or porosities that differ from those assigned to Standard Reference Material No.

When standardization is required in order to achieve agreement between test method A and test method B, the apparatus shall be standardized according to the requirements prescribed.

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

The disk shall be constructed of noncorroding metal, and shall fit the inside of the cell snugly.

  CHRISTOPH RANSMAYR DIE LETZTE WELT PDF

Although the test method may be, and has been, used for the determination of the measures of fineness of various other materials, it should be sstm that, in general, relative rather adtm absolute fineness values are obtained. This test method covers determination of the fineness of hydraulic cement, using the Blaine air-permeability apparatus, in terms of the specific surface expressed as total surface area in square centimetres per gram, or square metres per kilogram, of cement.

Historical Version s – view previous versions of standard. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. The timer shall have a positive starting and stopping mechanism.

Although the test method may be, and has been, used for the determination of the measures of fineness of various other materials, it should be understood that, in general, relative rather than absolute fineness values are obtained.

It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. The Blaine air-permeability apparatus consists essentially of a means of drawing a definite quantity of air through a prepared bed of cement of definite porosity.

The plunger shall be constructed of austenitic stainless steel and shall fit into the cell. This abstract is a brief summary of the referenced standard.

ASTM C Fineness of Hydraulic Cement | CTLGroup

Test Method A is the Reference Test Method using the manually operated standard Blaine apparatus, while Test Method B permits the use of automated apparatus that has in accordance with the qualification requirements of this test method demonstrated acceptable performance.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Work Item s – proposed revisions of this standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

  DISTANT STAR BOLANO PDF

The calibration of the air permeability apparatus shall be made using the standard reference material. The permeability cell shall consist of a rigid cylinder, constructed of austenitic stainless steel.

However, the user should exercise judgement in determining its suitability with regard to fineness measurements of cements with densities, or porosities that differ from those assigned to Standard Reference Material No. The automated test method shall employ apparatus designed either on the principles of the Blaine air-permeability method or apparatus based on the air-permeability principles of the Lea and Nurse method.

Work Item s – proposed revisions of this standard. The manometer shall be filled to the midpoint line with a nonvolatile, nonhygroscopic liquid of low viscosity and density. Historical Version s – view previous versions of standard Work Item s – proposed revisions of astn standard Translated Version s: When the specific surface values determined by an automated apparatus are to be used for acceptance or rejection of cement, the method used shall comply with the qualification requirements.

Active view current version of standard.

ASTM C Standard

Two test methods are given: Test Method A is the Reference Test Method using the manually operated standard Blaine apparatus, while Test Method B permits the use of automated apparatus that has in accordance with the 2c04 requirements of this test method demonstrated acceptable performance. Link to Active This link will always route to the current Active version of the standard. Two test methods are given: